DocumentCode :
2977477
Title :
Noise reduction in echocardigraphy images using Contourlet transform
Author :
Shahi, Laleh Panjeh ; Behnam, Hamid ; Shalbaf, Ahmad ; Sani, Zahra Alizadeh
Author_Institution :
E-learning Center, Iran Univ. of Sci., Tehran, Iran
fYear :
2011
fDate :
21-24 Feb. 2011
Firstpage :
420
Lastpage :
423
Abstract :
Echocardiographic images have considerable noises (Especially speckle noise) because of their inherent nature and do not have desirable quality which makes difficult to analyze them. Therefore, it is essential to run pre-processing to reduce noises before their interpretation and analysis. In this paper, we have used Contourlet method to reduce the noise of echocardiographic images. In order to evaluate and compare the proposed method with some common de noising methods, three different criteria (mean square error (MSE), peak signal-to-noise ratio and signal to mean square error) are used. The results showed that the proposed method is much better than the other methods. Moreover, according to expert echo cardiologist opinion, we have achieved maximum resolution other common de noising methods.
Keywords :
echocardiography; medical signal processing; signal denoising; contourlet transform; denoising methods; echo cardiologist; echocardigraphy images; mean square error; noise reduction; peak signal-to-noise ratio; Filter banks; Laplace equations; Noise; Speckle; Transforms; Wiener filter; Contourlet; Speckle noise; echocardiography images;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Biomedical Engineering (MECBME), 2011 1st Middle East Conference on
Conference_Location :
Sharjah
Print_ISBN :
978-1-4244-6998-7
Type :
conf
DOI :
10.1109/MECBME.2011.5752154
Filename :
5752154
Link To Document :