DocumentCode
2978858
Title
Technique to improve IGBT converter efficiency and transient response
Author
Turner, Robert W. ; Walton, Simon ; Duke, Richard
Author_Institution
Vectek Electron. Ltd., Napier
fYear
2008
fDate
1-3 Sept. 2008
Firstpage
528
Lastpage
535
Abstract
For medium to large power converters (1 kW to 100 MW) the switching frequency is limited to ensure acceptable losses at the cost of converter performance (bandwidth). A technique is presented that dynamically changes the switching frequency to maintain a low average switching frequency but for transient events shorter than the thermal time constant of the device, the switching frequency and bandwidth are increased. Relationships between the switching frequency and bandwidth are developed, and a method for determining when and how to change bandwidths is introduced. The technique is shown to give improvements in THD compared to a fixed frequency system of the same average switching frequency (same losses) in a harmonic filter application.
Keywords
insulated gate bipolar transistors; switching convertors; IGBT converter efficiency; harmonic filter; power 1 kW to 100 MW; power converters; transient response; Bandwidth; Delay; Hysteresis; Insulated gate bipolar transistors; Pulse width modulation; Pulse width modulation converters; Switching converters; Switching frequency; Switching loss; Transient response; AC/AC Converter; Converter Control; Efficiency; IGBT; PWM; Parallel Operation; Power Quality;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics and Motion Control Conference, 2008. EPE-PEMC 2008. 13th
Conference_Location
Poznan
Print_ISBN
978-1-4244-1741-4
Electronic_ISBN
978-1-4244-1742-1
Type
conf
DOI
10.1109/EPEPEMC.2008.4635320
Filename
4635320
Link To Document