DocumentCode :
298215
Title :
Control of the vacuum vessel temperature in RFX
Author :
Campostrini, P.P. ; Fauri, M. ; Marchiori, G. ; Sonato, P. ; Vitturi, S. ; Zollino, G.
Author_Institution :
Padova Univ., Italy
Volume :
1
fYear :
1993
fDate :
11-15 Oct 1993
Firstpage :
223
Abstract :
The vacuum vessel of RFX has been designed to operate between room temperature and 350°C during experimental sessions and during first wall conditioning operations. The temperature control system of the vacuum vessel consists of the measurement and the heating systems, connected to the RFX central control system, SIGMA. The data acquisition electronics supplies the temperature signals to the heating system and to SIGMA. The heating system provides uniform heating in both toroidal and poloidal directions. SIGMA allows different modes of operation and handles the alarm signals. After a description of the main components, the results of the first two years of operation are presented
Keywords :
data acquisition; fusion reactor design; fusion reactor instrumentation; plasma-wall interactions; reversed field pinch; temperature control; 20 to 350 C; RFX; RFX central control system; SIGMA; alarm signals; data acquisition electronics; first wall conditioning operations; heating systems; poloidal directions; toroidal directions; vacuum vessel temperature control; Cable insulation; Cable shielding; Centralized control; Control systems; Cooling; Heating; Plasma temperature; Temperature control; Temperature measurement; Temperature sensors;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Fusion Engineering, 1993., 15th IEEE/NPSS Symposium on
Conference_Location :
Hyannis, MA
Print_ISBN :
0-7803-1412-3
Type :
conf
DOI :
10.1109/FUSION.1993.518319
Filename :
518319
Link To Document :
بازگشت