DocumentCode
298232
Title
Space- and time-dependent residual radioactivity distribution in the TFTR coil coolant during DT operation
Author
Ku, L.P. ; Liew, S.L.
Author_Institution
Plasma Phys. Lab., Princeton Univ., NJ, USA
Volume
1
fYear
1993
fDate
11-15 Oct 1993
Firstpage
305
Abstract
We have examined the space and time dependent residual radioactivities induced by the neutrons in the TFTR coil coolant for DT operation. A system of nodal equations describing the changes in the radionuclide concentration throughout the entire coolant flow network was constructed and solved to derive the dose equivalent rate of exposure. The results indicate that an unrestricted access to the basement and pump area can be made only after at least 2 minutes of cooling after a full power discharge
Keywords
Tokamak devices; cooling; dosimetry; fusion reactor safety; fusion reactor theory; radioactivity; TFTR; coil coolant; cooling system; dose equivalent rate; poloidal field coil; radionuclide concentration; residual radioactivity; toroidal field coil; Coils; Coolants; Cooling; Neutrons; Physics; Plasmas; Production; Protection; Radiation safety; Tokamaks;
fLanguage
English
Publisher
ieee
Conference_Titel
Fusion Engineering, 1993., 15th IEEE/NPSS Symposium on
Conference_Location
Hyannis, MA
Print_ISBN
0-7803-1412-3
Type
conf
DOI
10.1109/FUSION.1993.518336
Filename
518336