DocumentCode :
2982721
Title :
Rotor turn-to-turn faults of doubly-fed Induction generators in wind energy plants - modelling, simulation and detection -
Author :
Dinkhauser, Vincenz ; Fuchs, Friedrich W.
Author_Institution :
Inst. of Power Electron. & Electr. Drives, Christian-Albrechts-Univ. of Kiel, Kiel
fYear :
2008
fDate :
1-3 Sept. 2008
Firstpage :
1819
Lastpage :
1826
Abstract :
This work considers the seldomly treated case of rotor turn-to-turn fault of a doubly-fed induction generator. This fault can take place where the doubly-fed induction generator is a standard solution in wind power stations. For investigations an error-adoptable three phase machine model is derived and simulated. Furthermore the model is integrated in a wind energy plant model and simulated for a turn-to-turn fault in one rotor phase. Motor current signature analysis, wavelet transformation and the Luenberger observer are used for detection and are compared.
Keywords :
asynchronous generators; fault simulation; observers; rotors; wavelet transforms; wind power plants; Luenberger observer; doubly-fed induction generators; error-adoptable three phase machine model; fault detection; fault simulation; motor current signature analysis; rotor turn-to-turn faults; wavelet transformation; wind energy plants; Electrical fault detection; Fault detection; Induction generators; Induction machines; Power electronics; Rotors; Stators; Strontium; Voltage; Wind energy; Diagnostics; Fault handling strategy; Simulation; Wind energy; doubly-fed induction machine;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics and Motion Control Conference, 2008. EPE-PEMC 2008. 13th
Conference_Location :
Poznan
Print_ISBN :
978-1-4244-1741-4
Electronic_ISBN :
978-1-4244-1742-1
Type :
conf
DOI :
10.1109/EPEPEMC.2008.4635530