DocumentCode
298677
Title
Measurement techniques for the 3rd PEP round robin
Author
Roes, R.F.M. ; Zaaiman, W.J. ; Ossenbrink, H.A.
Author_Institution
Grantholder Enschede Polytech., Netherlands
Volume
1
fYear
1994
fDate
5-9 Dec 1994
Firstpage
863
Abstract
This paper describes the measurement techniques used for the calibration of the Newer Technology reference solar cells for the 3rd PEP Round Robin, held from 1993 to 1995. The current-voltage characteristics of the devices under test are not only measured close to standard test conditions (STC), but also at a number of different temperatures, allowing the temperature coefficients α and β as well as the curve correction factor κ to be established. Linearity measurements, with respect to the short-circuit current Isc and the open-circuit voltage Voc, are performed and series resistance of cells is determined. An extrapolation procedure is used to correct the output parameters to STC
Keywords
calibration; electric current measurement; electric resistance measurement; extrapolation; solar cells; temperature measurement; voltage measurement; 3rd PEP Round Robin; calibration; current-voltage characteristics; curve correction factor; extrapolation procedure; linearity measurements; measurement techniques; open-circuit voltage; reference solar cells; series resistance determination; short-circuit current; spectral response measurements; standard test conditions; temperature coefficients; Calibration; Current measurement; Current-voltage characteristics; Linearity; Measurement standards; Measurement techniques; Photovoltaic cells; Round robin; Temperature; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Photovoltaic Energy Conversion, 1994., Conference Record of the Twenty Fourth. IEEE Photovoltaic Specialists Conference - 1994, 1994 IEEE First World Conference on
Conference_Location
Waikoloa, HI
Print_ISBN
0-7803-1460-3
Type
conf
DOI
10.1109/WCPEC.1994.520097
Filename
520097
Link To Document