DocumentCode
298679
Title
Spectral response calibration facility for photovoltaic cells
Author
Budde, R. ; Zaaiman, W. ; Ossenbrink, H.A.
Author_Institution
Grantholder Enschede Polytech., Netherlands
Volume
1
fYear
1994
fDate
5-9 Dec 1994
Firstpage
874
Abstract
This paper describes a secondary calibration method for determining the absolute spectral responsivity of photovoltaic cells. The test facility uses the reference cell method for determination of the relative responsivity. Using the known absolute responsivity data of the reference cell, the absolute spectral responsivity of the test cell is calculated. The whole measurement is controlled by a PC
Keywords
calibration; computerised instrumentation; microcomputer applications; semiconductor device testing; solar cells; test facilities; PC; measurement; photovoltaic cells; reference cell method; relative responsivity; spectral response calibration facility; test facility; Calibration; Filters; Lamps; Light sources; Performance evaluation; Photovoltaic cells; Short circuit currents; Testing; Wavelength measurement; Wheels;
fLanguage
English
Publisher
ieee
Conference_Titel
Photovoltaic Energy Conversion, 1994., Conference Record of the Twenty Fourth. IEEE Photovoltaic Specialists Conference - 1994, 1994 IEEE First World Conference on
Conference_Location
Waikoloa, HI
Print_ISBN
0-7803-1460-3
Type
conf
DOI
10.1109/WCPEC.1994.520100
Filename
520100