DocumentCode :
2992421
Title :
ATP representation of cycloconverter drives for rolling mills: a useful tool for protection design purposes
Author :
Ceroni, M. ; Fellin, L. ; Mari, A. ; Mattavelli, P. ; Bordignon, P. ; Radrizzani, L.
Author_Institution :
Dept. of Electr. Eng., Padova Univ., Italy
fYear :
1998
fDate :
1998
Firstpage :
61
Lastpage :
68
Abstract :
A cycloconverter drive for a rolling mill is considered and a detailed modelling of the system obtained by means of ATP (Alternative Transient Program) is presented, as regards power and control circuits as well as the protection devices and logic. The techniques for achieving a proper model are then illustrated and a case study is presented to show the use of the model for evaluating the fault effects on a real system. A modular approach based on the use of an ATP graphical interface is adopted for system representation, which also makes the tool suitable for nonprofessional ATP programmers
Keywords :
cycloconvertors; graphical user interfaces; power engineering computing; protection; rolling mills; synchronous motor drives; transient analysis; ATP graphical interface; ATP representation; Alternative Transient Program; control circuits; cycloconverter drives; fault effects evaluation; logic; modular approach; nonprofessional ATP programmers; power circuits; protection design purposes; protection devices; rolling mills; synchronous motor drive; Circuit faults; Computer industry; Industrial plants; Logic design; Logic devices; Milling machines; Power system modeling; Power system protection; Programming profession; Synchronous motors;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Computers in Power Electronics, 1998. 6th Workshop on
Conference_Location :
Cernobbio
ISSN :
1093-5142
Print_ISBN :
0-7803-4856-7
Type :
conf
DOI :
10.1109/CIPE.1998.779659
Filename :
779659
Link To Document :