DocumentCode :
2994911
Title :
The collection volume method for lightning protectors placement on naval ships
Author :
Hossam-Eldin, Ahmed A. ; Omran, Ehab A M
Author_Institution :
Alexandria Univ., Alexandria
fYear :
2007
fDate :
14-17 Oct. 2007
Firstpage :
512
Lastpage :
516
Abstract :
This paper investigates and demonstrates a developed technique to use the collection volume method (CVM), for the placement of either conventional or non-conventional lightning protection systems (LPS) for ships. Each lightning eliminator assigned a striking distance, which is calculated as a function of ship height, radius of curvature, ship location, ship dimensions, risk factor, and lightning related parameters. This novel technique was applied to a medium war ship, cargo, destroyer, as well as an air craft carrier, and showed to be a very efficient mean for lightning protection for these ships. For some design cases, a hybrid system was chosen to be the most efficient and the less expensive system.
Keywords :
electric variables measurement; lightning protection; ships; CVM; aircraft carrier; cargo ship; collection volume method; curvature radius; destroyer ship; lightning eliminator; lightning protector placement; lightning related parameters; medium warship; naval ships; nonconventional LPS; risk factor; ship dimensions; ship height; ship location; striking distance; Conductivity; Contacts; Dielectrics and electrical insulation; Electric breakdown; Lightning protection; Marine vehicles; Radar antennas; Rubber; Shape; Sprites (computer); Air Terminal; Collection Voume; DAS; ESE; Lightning Protection; Marine Ships; Rolling Sphere; Transient;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation and Dielectric Phenomena, 2007. CEIDP 2007. Annual Report - Conference on
Conference_Location :
Vancouver, BC
Print_ISBN :
978-1-4244-1482-6
Electronic_ISBN :
978-1-4244-1482-6
Type :
conf
DOI :
10.1109/CEIDP.2007.4451453
Filename :
4451453
Link To Document :
بازگشت