Title :
Improvements of the variable thermal resistance
Author :
Székely, V. ; Török, S. ; Kollár, E.
Author_Institution :
Budapest Univ. of Technol. & Econ., Budapest
Abstract :
A flat mounting unit with electronically variable thermal resistance has been presented in the last year. The design was based on a Peltier cell and the appropriate control electronics and software. The device is devoted especially to the thermal characterization of packages, e.g. in dual cold plate arrangements. Although this design meets the requirements of the static measurement we are intended to improve its parameters as the settling time and dynamic thermal impedance and the range of realized thermal resistance. The new design applies the heat flux sensor developed by our team as well, making easier the control of the device. This development allows even the realization of negative thermal resistances.
Keywords :
Peltier effect; temperature sensors; thermal management (packaging); thermal resistance; Peltier cell; dynamic thermal impedance; flat mounting unit; heat flux sensor; package thermal characterization; variable thermal resistance; Cold plates; Electric variables control; Electrical resistance measurement; Electronic packaging thermal management; Impedance measurement; Sensor phenomena and characterization; Thermal resistance; Thermal sensors; Thermal variables control; Time measurement; DCP measurements; Peltier cell; heat-flux sensor; variable thermal resistance;
Conference_Titel :
Thermal Investigation of ICs and Systems, 2007. THERMINIC 2007. 13th International Workshop on
Conference_Location :
Budapest
Print_ISBN :
978-2-35500-002-7
DOI :
10.1109/THERMINIC.2007.4451773