DocumentCode
3005221
Title
Study on new leading-out mode of neutral points of large-sized turbo-generator
Author
Gui, L. ; Wang, X.H. ; Sun, Y.G. ; Wang, W.J.
Author_Institution
Dept. of Electr. Eng., Tsinghua Univ., Beijing, China
Volume
1
fYear
2005
fDate
27-29 Sept. 2005
Firstpage
89
Abstract
To supply overall protection for large-sized turbo-generator, a new approach about leading-out mode of neutral points and disposition of protection schemes is firstly presented in this paper. To check up the sensitivity of the new protection scheme, two turbo-generators with 300 MW are simulated using the multi-loop method. Simulation results indicate the performance of the new protection scheme is much better than that of the traditional protection. Without adding hardware investment, the new leading-out mode is agreed by electrical machine designers.
Keywords
machine protection; sensitivity; turbogenerators; 300 MW; large-sized turbo-generator; leading-out mode; multiloop method; neutral points; overall protection; Current transformers; Hardware; Laboratories; Power generation; Power system control; Power system protection; Power system simulation; Power systems; Stator windings; Sun;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Machines and Systems, 2005. ICEMS 2005. Proceedings of the Eighth International Conference on
Print_ISBN
7-5062-7407-8
Type
conf
DOI
10.1109/ICEMS.2005.202491
Filename
1574724
Link To Document