DocumentCode
300910
Title
Spectral and spatial characteristics of X-ray film detectors in the wavelength range 20-150
Author
Fedin, D.A. ; Fedorchuk, R.V. ; Gullikson, E. ; Koshevoi, M.O. ; Lukjantsev, I.V. ; Rupasov, A.A. ; Shikanov, A.S.
Author_Institution
P.N. Lebedev Phys. Inst., Acad. of Sci., Moscow, Russia
Volume
1
fYear
1995
fDate
30 Sep-5 Oct 1995
Firstpage
53
Abstract
Investigations of spectral sensitivity, contrast coefficient, and spatial resolution of widely used x-ray films have been undertaken at the P.N. Lebedev Institute. A description of experimental methodologies and results are presented. These studies were carried out using synchrotron radiation in the range of 20-150 Å. Spectral sensitivity and contrast coefficient dependencies on wave-length for Kodak 10106, DEF, RAR2490, and TPF films and spatial resolution for Kodak 10106 and RAK2490 films are presented and discussed
Keywords
X-ray detection; nuclear track emulsions; photographic material sensitivity; DEF; Kodak 10106; RAK2490 film; RAR2490; TPF film; X-ray film detectors; contrast coefficient; spatial characteristics; spatial resolution; spectral characteristics; spectral sensitivity; synchrotron radiation; Gratings; Radiation detectors; Spatial resolution; Spectrogram; Spectroscopy; Strontium; Synchrotron radiation; Testing; X-ray detection; X-ray detectors;
fLanguage
English
Publisher
ieee
Conference_Titel
Fusion Engineering, 1995. SOFE '95. Seeking a New Energy Era., 16th IEEE/NPSS Symposium
Conference_Location
Champaign, IL
Print_ISBN
0-7803-2969-4
Type
conf
DOI
10.1109/FUSION.1995.534174
Filename
534174