Study of Pulsed Power Supply for Magnetoacoustic Tomography with Magnetic Induction
Author :
Li, Yanhong ; Liu, Guoqiang ; Li, Shiqiang
Author_Institution :
Dept. of the Frontiers in Electr. Eng., Chinese Acad. of Sci., Beijing, China
fYear :
2010
fDate :
25-27 June 2010
Firstpage :
4266
Lastpage :
4270
Abstract :
To develop image logging technology, this paper studies array magnetoacoustic tomography with magnetic induction(MAT-MI) on the basis of contrasting the research of home and abroad. Through design, computer simulation and experiment studies on generating system of pulsed magnetic field, we demonstrated that the pulsed power supply can realize narrow width, high peak and repeat pulsed current with inductive load, then pulsed magnetic field is generated in the coil. Magnetoacoustic tomography with magnetic induction combines the technology of Electrical Impedance Tomography and ultrasonic imaging, it can provide an impedance image with good accuracy and high spatial resolution, the method has a good prospect of application and extension in geophysical prospecting, medical imaging and other fields.
Keywords :
electric impedance imaging; electromagnetic induction; magnetoacoustic effects; pulsed power supplies; tomography; electrical impedance tomography; image logging technology; magnetic induction; magnetoacoustic tomography; pulsed magnetic field; pulsed power supply; ultrasonic imaging; Coils; Converters; Inductance; Magnetic resonance imaging; Magnetoacoustic effects; Switches; Tomography; LCC resonant; magnetoacoustic tomography with magnetic induction; pulsed magnetic field; pulsed power supply;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical and Control Engineering (ICECE), 2010 International Conference on
Conference_Location :
Wuhan
Print_ISBN :
978-1-4244-6880-5
Type :
conf
DOI :
10.1109/iCECE.2010.1037