Abstract
The high density polyethylene is one of the units downstream of Olefin plant. Its main feedstock is ethylene after which with the catalyst are converted into high density polyethylene as the final product. The most important components of this plant contain reactor, centrifuge and extruder. Good performance of the centrifuge is considered an important role as determining the capacity of the unit. Hence continuous condition monitoring of this equipment will act in achieving this goal significantly. One of the problems in centrifuge equipment have been seen to modulate vibration on the medium voltage electromotor of centrifuge. Increasing of vibration due to imbalance between centrifuge components during a long time will result in cracking junction box of the electromotor. To verify this problem and remove imbalance of centrifuge components will be prevented more damages and failures of electromotor in future.
Keywords
centrifuges; condition monitoring; electric motors; failure analysis; polymers; production facilities; vibrations; Olefin plant; body failure; centrifuge equipment; condition monitoring; high density polyethylene plant; junction box; medium voltage electromotor; Fasteners; Frequency modulation; Junctions; Polyethylene; Powders; Suspensions; Vibrations; Balance; Beat Vibration; Centrifuge or Decanter; Modulation;
fLanguage
English
Publisher
ieee
Conference_Titel
Condition Monitoring and Diagnosis (CMD), 2012 International Conference on
Conference_Location
Bali
Print_ISBN
978-1-4673-1019-2
Type
conf
DOI
10.1109/CMD.2012.6416249
Filename
6416249
Link To Document