  • Title

    Fundamental study on residual charge detection with pulse voltages as diagnostic method of water tree-degraded XLPE cables

  • Author

    Kurihara, Takashi ; Okamoto, Tatsuaki ; Tsuji, Takao ; Uchida, Kazunori ; Myong Hwan Kim ; Hozumi, N.

  • Author_Institution
    Central Res. Inst. of Electr. Power Ind., Yokosuka, Japan
  • fYear
    2012
  • fDate
    23-27 Sept. 2012
  • Firstpage
    84
  • Lastpage
    87
  • Abstract
    The residual charge method is one of the main degradation diagnostic methods for water tree degradation of XLPE cables. In this method, a DC voltage is applied to a water tree-degraded XLPE cable in order to accumulate space charges in water tree parts of an XLPE cable, and an AC voltage is applied to it in order to release deeply trapped space charges, i.e. residual charges. The authors have been developing a new diagnostic method with pulse voltages instead of DC and AC voltages since the method can be applied to the XLPE cables that are connected to gas insulated switchgears. If a diagnostic method using pulse voltages for water tree-degraded XLPE cables is developed, the improvement of the detection sensibility for signals related to water trees is expected because of the averaging effect of signals by the repeated application of pulse voltages in a time that is shorter than conventional method. The diagnostic method with pulse voltages enables us to use more compact and lightweight high voltage devices. In this study, we applied pulse voltages with the pulse widths ranging from 1 to 10ms to an artificial water tree-degraded XLPE cable and a removed XLPE cable with a class of 6.6kV, and successfully detected current signals related to water tree degradation.
  • Keywords
    XLPE insulation; gas insulated switchgear; power cables; AC voltage; DC voltage; artificial water tree-degraded XLPE cables; compact high voltage devices; deeply trapped space charges; diagnostic method; gas insulated switchgears; lightweight high voltage devices; pulse voltages; residual charge detection; time 1 ms to 10 ms; voltage 6.6 kV; Cable insulation; Charge measurement; Current measurement; Degradation; Power cables; Trees - insulation; Voltage measurement; XLPE cable; degradation diagnostic method; pulse voltage; residual charge method; water trees;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Condition Monitoring and Diagnosis (CMD), 2012 International Conference on
  • Conference_Location
    Bali
  • Print_ISBN
    978-1-4673-1019-2
  • Type

    conf

  • DOI
    10.1109/CMD.2012.6416265
  • Filename
    6416265