DocumentCode :
3012408
Title :
Feasibility study on a new visualization technique of discharge-emitted electromagnetic waves with time-domain measurements
Author :
Shibata, Hajime ; Umegane, T. ; Ohtsuka, Shigeki
Author_Institution :
Dept. of Electr. Eng. & Electron., Kyushu Inst. of Technol., Kitakyushu, Japan
fYear :
2012
fDate :
23-27 Sept. 2012
Firstpage :
1197
Lastpage :
1200
Abstract :
As for the insulation diagnosis of the electric power apparatus and the measurement of electromagnetic interference (EMI), a position location technique of the electromagnetic(EM) wave radiation source is required. Although there are many researches on the position location technique of the EM wave radiation source, it still remains the difficulties to readily understanding the result, i.e., the position of the source, and to immediately recognize the validity of the result. From this point of view, we have newly developed a visualization equipment of EM wave radiation source with a new visualization idea using the time-domain measurement technique. The frequency band of the antenna was selected to detect the UHF band signals because of the consideration of the insulation diagnosis by the UHF method for the power apparatus as well as the detection of electrostatic discharge(ESD). From this point of view, feasibility study has carried out and lots of advantages of this visualization method was experimentally confirmed. In this paper, we firstly introduced the concept of the proposed visualization method and the configuration of the system. Then, we showed the application results of this visualization equipment to the corona discharge generated in a real outdoor substation.
Keywords :
UHF antennas; corona; electrostatic discharge; power apparatus; radiofrequency interference; substation insulation; time-domain analysis; EM wave radiation source; EMI; ESD detection; UHF band signal; antenna frequency band; corona discharge generation; discharge-emitted electromagnetic waves; electric power apparatus; electromagnetic interference measurement; electrostatic discharge; insulation diagnosis; position location technique; power apparatus; substation; time-domain measurement; visualization equipment; Condition monitoring; Conferences; Decision support systems; Diagnosis; Electromagnetic wave; Position location; Visualization;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Condition Monitoring and Diagnosis (CMD), 2012 International Conference on
Conference_Location :
Bali
Print_ISBN :
978-1-4673-1019-2
Type :
conf
DOI :
10.1109/CMD.2012.6416375
Filename :
6416375
Link To Document :
بازگشت