Study on rotor magnetomotive force comparison of doubly-fed brushless machine with cage rotor or wound rotor
Author
Guangzhong, Li ; Xiaoping, Ding ; Qianghui, Xiao ; Feng, Zhou
Author_Institution
Hunan Inst. of Eng., Xiantan
Volume
3
fYear
2005
fDate
29-29 Sept. 2005
Firstpage
2059
Abstract
This paper detailedly studies the rotor magnetomotive force of doubly-fed brushless machine with cage or wound rotor, comparatively analyzes the magnetomotive force produced by rotor conductor at unit conductor on the condition that the rotor slot occupancy ratio and the conductor numbers are in consistency, and points out that, for of doubly-fed brushless motor, the efficiency of magnetomotive force of wound-type rotor is better than that of cage-type rotor
Keywords
brushless machines; rotors; cage rotor; doubly-fed brushless machine; rotor conductor; rotor magnetomotive force; wound rotor; Brushless machines; Brushless motors; Conductors; Induction motors; Magnetic analysis; Magnetic fields; Rotors; Stator windings; Synchronous motors; Wounds; Brushless Machine; Cage Rotor; Doubly-fed; Rotor Magnetometive Force; Wound Rotor;