• DocumentCode
    3012564
  • Title

    Improving the radiation properties of a piezoceramic air ultrasound transducer by adding a ceramic membrane

  • Author

    Medek, R. ; Kellner, J. ; Schweinzer, H.

  • Author_Institution
    Dept. of Appl. Electron. Mater., Vienna Univ. of Technol., Vienna, Austria
  • fYear
    2009
  • fDate
    13-17 May 2009
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    Ultrasound systems based on piezoceramic transducers have the disadvantageous property of poor acoustical impedance matching to air leading to relative low ultrasound pressure output in spite of high driving voltages. In order to increase the output of the transducer a thin ceramic membrane (LTCC Low Temperature Cofired Ceramic) is mounted on the piezoceramic material. With the mounted membrane, the measured ultrasound pressure is more than three times as high as without the membrane at the same driving voltage. First results of this new type of transducer will be presented in this work.
  • Keywords
    ceramics; ultrasonic transducers; acoustical impedance; ceramic membrane; driving voltage; piezoceramic air ultrasound transducer; radiation properties; thin ceramic membrane; Acoustic measurements; Acoustic transducers; Biomembranes; Ceramics; Impedance matching; Piezoelectric materials; Temperature; Ultrasonic imaging; Ultrasonic transducers; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electronics Technology, 2009. ISSE 2009. 32nd International Spring Seminar on
  • Conference_Location
    Brno
  • Print_ISBN
    978-1-4244-4260-7
  • Type

    conf

  • DOI
    10.1109/ISSE.2009.5207067
  • Filename
    5207067