DocumentCode :
3014268
Title :
Closing the feedback loop in the half-bridge complementary-control DC-to-DC converter
Author :
Linera, F.F. ; Sebastián, J. ; García ; Díaz, J. ; Fontan, A.
Author_Institution :
Oviedo Univ., Spain
Volume :
2
fYear :
1997
fDate :
23-27 Feb 1997
Firstpage :
977
Abstract :
The half-bridge complementary-control converter (HBCC) has been proposed as a good solution for a low-output voltage DC-to-DC converter. A study of the dynamic of this converter using a symmetrical isolation transformer has already been introduced. This paper shows a generalization of the study using an asymmetric transformer. Some practical design rules have been proposed to facilitate the design of the compensation network. Finally, a dynamic study of the peak control current mode is presented
Keywords :
DC-DC power convertors; bridge circuits; compensation; electric current control; feedback; transformers; asymmetric transformer; compensation network design; dynamic study; feedback loop closing; half-bridge complementary-control DC-to-DC converter; low-output voltage DC-to-DC converter; peak control current mode; Capacitors; Circuits; DC-DC power converters; Feedback loop; Filters; Inductance; Low voltage; Rectifiers; Stress; Telecommunications;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Applied Power Electronics Conference and Exposition, 1997. APEC '97 Conference Proceedings 1997., Twelfth Annual
Conference_Location :
Atlanta, GA
Print_ISBN :
0-7803-3704-2
Type :
conf
DOI :
10.1109/APEC.1997.575766
Filename :
575766
Link To Document :