• DocumentCode
    3015936
  • Title

    Non-stationary signal analysis in water pipes monitoring

  • Author

    Mocanu, D. ; Ballester, J.L. ; Ioana, C.

  • Author_Institution
    Grenoble INP/PHELMA, Grenoble, France
  • fYear
    2010
  • fDate
    7-10 Nov. 2010
  • Firstpage
    1348
  • Lastpage
    1352
  • Abstract
    In order to develop early failure detection tools for hydro-power plants, “Electricite de France” (EDF) has equipped its high pressure pipes with sensors which monitor the pressure surge transients, the position of the intake and overpressure valves. The control valves are constructed so that the pressure will not exceed a maximum threshold called the Maximum Guaranteed Pressure (MGP). Modifications in the normal behavior of these control valves can generate high pressure surges over passing the MGP. In this paper, several methods which allow predicting the anomalies in the normal behavior of the hydro-power plant system will be presented.
  • Keywords
    failure analysis; hydroelectric power; monitoring; pipes; valves; control valve; failure detection tool; high pressure pipe; hydropower plant system; intake valve; maximum guaranteed pressure; nonstationary signal analysis; overpressure valve; water pipe monitoring; Heuristic algorithms; Signal processing algorithms; Surge protection; Surges; Time series analysis; Trajectory; Valves; Transient analysis; dynamic time warping; recurrence plot analysis; water-hammer;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Signals, Systems and Computers (ASILOMAR), 2010 Conference Record of the Forty Fourth Asilomar Conference on
  • Conference_Location
    Pacific Grove, CA
  • ISSN
    1058-6393
  • Print_ISBN
    978-1-4244-9722-5
  • Type

    conf

  • DOI
    10.1109/ACSSC.2010.5757752
  • Filename
    5757752