Title :
A kinematic error model for a parallel Gantry-Tau manipulator
Author :
Dressler, Isolde ; Brogårdh, Torgny ; Robertsson, Anders
Author_Institution :
Dept. of Autom. Control, Lund Univ., Lund, Sweden
Abstract :
Parallel robots are generally said to be more accurate but to have a smaller workspace compared to serial robots. With the Gantry-Tau robot, a parallel robot with a large, reconfigurable workspace was presented. This article tries to identify the maximum achievable end-effector positioning accuracy of the Gantry-Tau robot. To this end, a couple of new kinematic error models are presented and evaluated. The sources of the remaining positioning errors (0.09 mm) are discussed.
Keywords :
manipulator kinematics; position control; Gantry-Tau robot; end-effector positioning accuracy; kinematic error model; parallel Gantry-Tau manipulator; parallel robots; Calibration; Error correction; Kinematics; Manipulators; Manufacturing processes; Parallel robots; Prototypes; Robot sensing systems; Robotics and automation; Service robots;
Conference_Titel :
Robotics and Automation (ICRA), 2010 IEEE International Conference on
Conference_Location :
Anchorage, AK
Print_ISBN :
978-1-4244-5038-1
Electronic_ISBN :
1050-4729
DOI :
10.1109/ROBOT.2010.5509512