DocumentCode :
3022739
Title :
Method of Extracting Unloaded Q Applied Across Different Resonator Technologies
Author :
Ruby, Rich ; Parker, Reed ; Feld, Dave
Author_Institution :
Wireless Semicond. Div., Avago Technol., San Jose, CA
fYear :
2008
fDate :
2-5 Nov. 2008
Firstpage :
1815
Lastpage :
1818
Abstract :
When comparing different resonator technologies, it is essential that fundamental properties such as the unloaded Q be accurately portrayed. Important Figure-of-Merit (FOM) numbers for resonators include operating frequency, coupling coefficient (kt2), Q, and the products - - kt2*Q and f*Q. Three of the five Figure´s of Merit depend on an accurate evaluation of unloaded Q. Using a new equation for Q (derived from first principles), we can measure both Q and the coupling coefficient for a variety of resonator technologies and compare the relative performance metrics of each technology.
Keywords :
Q-factor; acoustic resonators; ultrasonic devices; Figure-of-Merit numbers; coupling coefficient; operating frequency; resonator technologies; unloaded Q extraction; Band pass filters; Cellular phones; Electrical resistance measurement; Equations; Film bulk acoustic resonators; Q measurement; Resonance; Resonant frequency; Resonator filters; Scattering parameters;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Ultrasonics Symposium, 2008. IUS 2008. IEEE
Conference_Location :
Beijing
Print_ISBN :
978-1-4244-2428-3
Electronic_ISBN :
978-1-4244-2480-1
Type :
conf
DOI :
10.1109/ULTSYM.2008.0446
Filename :
4803460
Link To Document :
بازگشت