DocumentCode :
3029403
Title :
Optimization of parameters for 3-D reconstruction with uncalibrated monoplane angiograms
Author :
Wang, Guozhu ; Zhang, Tianxu ; Ma, Jinfeng
Author_Institution :
Inst. for Pattern Recognition & Artificial Intell., Huazhong Univ. of Sci. & Technol., Wuhan, China
fYear :
2011
fDate :
26-28 July 2011
Firstpage :
606
Lastpage :
609
Abstract :
A method about optimization of parameters for 3-D reconstruction with uncalibrated monoplane angiograms is presented in this paper. Based on the model of monoplane angiographic system, variables concerning about the precision of reconstruction are discussed. Distance between initial image and projection of reconstructed 3-D model is employed to formulate objective function. Adaptive simulated annealing algorithm is utilized to solve the problem of optimization. Experiments on angiograms are presented. The results show that the method greatly improves the accuracy of 3-D reconstruction.
Keywords :
biomedical MRI; computer graphics; diagnostic radiography; image reconstruction; simulated annealing; 3D model reconstruction; adaptive simulated annealing algorithm; monoplane angiographic system; parameter optimization; uncalibrated monoplane angiograms; Arteries; Image reconstruction; Imaging; Simulated annealing; Three dimensional displays; X-ray imaging; 3-D reconstruction; adaptive simulated annealing algorithm; optimization; uncalibrated monoplane angiogram;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Multimedia Technology (ICMT), 2011 International Conference on
Conference_Location :
Hangzhou
Print_ISBN :
978-1-61284-771-9
Type :
conf
DOI :
10.1109/ICMT.2011.6002023
Filename :
6002023