Title :
Accuracy analysis for off-line array calibration
Author :
Friedlander, Benjamin ; Porat, Boaz
Author_Institution :
Dept. of Electr. Eng., Technion-Israel Inst. of Technol., Haifa, Israel
Abstract :
Practical sensor arrays are characterized by certain parameters, related to the array shape and its electrical properties. Accurate direction finding requires calibration of these parameters to a relatively high accuracy. Off-line calibration of the array parameters is performed by transmitting signals from known locations and measuring the array response. This paper relates the parameter estimation accuracy achieved in off-line calibration to the direction-of-arrival errors during on-line operation. It then proposes a criterion for choosing the off-line calibration points so as to meet on-line accuracy requirements
Keywords :
antenna arrays; antenna theory; calibration; direction-of-arrival estimation; accuracy analysis; accurate direction finding; array parameters; array response; array shape; direction-of-arrival errors; electrical properties; off-line array calibration; on-line operation; parameter estimation accuracy; practical sensor arrays; Antenna arrays; Antenna measurements; Calibration; Direction of arrival estimation; Directive antennas; Parameter estimation; Performance evaluation; Phased arrays; Sensor arrays; Transmitters;
Conference_Titel :
Acoustics, Speech, and Signal Processing, 1996. ICASSP-96. Conference Proceedings., 1996 IEEE International Conference on
Conference_Location :
Atlanta, GA
Print_ISBN :
0-7803-3192-3
DOI :
10.1109/ICASSP.1996.548001