• DocumentCode
    3029973
  • Title

    Current harmonic filtering of non-conventional non-linear load by current source active filter

  • Author

    Benchaits, I. ; Saadate, S.

  • Author_Institution
    CNRS, Vandoeuvre-les-Nancy, France
  • Volume
    2
  • fYear
    1996
  • fDate
    17-20 Jun 1996
  • Firstpage
    636
  • Abstract
    A current-source active power filter controlled by a new switching control method is presented. Its filtering efficiency is tested with two types of nonlinear load: a conventional load such as a six-pulse three-phase controlled rectifier; and a nonconventional load of a three-pulse 18-thyristor cycloconverter with balanced three-phase load. The principle of the control method which leads to a low total harmonic distortion (THD) is exposed. Analysis of the power circuit and simulation results are presented and discussed
  • Keywords
    AC-AC power convertors; AC-DC power convertors; active filters; cycloconvertors; harmonic distortion; load (electric); power filters; power system harmonics; rectifying circuits; THD; balanced three-phase load; current harmonic filtering; current source active filter; filtering efficiency; nonlinear electric load; six-pulse three-phase controlled rectifier; switching control method; three-pulse 18-thyristor cycloconverter; total harmonic distortion; Active filters; Circuits; Filtering; Hysteresis; Inverters; Power harmonic filters; Power system harmonics; Resonance; Switches; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industrial Electronics, 1996. ISIE '96., Proceedings of the IEEE International Symposium on
  • Conference_Location
    Warsaw
  • Print_ISBN
    0-7803-3334-9
  • Type

    conf

  • DOI
    10.1109/ISIE.1996.551016
  • Filename
    551016