DocumentCode
3033014
Title
Method for measuring mixed field radiation levels relevant for SEEs at the LHC
Author
Røed, Ketil ; Brugger, Markus ; Kramer, Daniel ; Peronnard, Paul ; Pignard, Christian ; Spiezia, Giovani ; Thornton, Adam
Author_Institution
CERN, Genève, Switzerland
fYear
2011
fDate
19-23 Sept. 2011
Firstpage
516
Lastpage
523
Abstract
At the LHC installed electronics will be exposed to a radiation field of mixed particles over a wide range of energies. While Monte Carlo transport codes can be used for calculations and predictions of radiation levels, the complex operation and layout of the LHC accelerator give rise to significant uncertainties. Dedicated radiation monitors are therefore installed in locations of the electronics to provide an on line measurement of the radiation levels. This paper addresses the method that has been applied to calibrate these radiation monitors for their use in mixed radiation fields. New irradiation tests to determine the sensitivity to neutrons from a few MeV to 20 MeV will be presented along with additional irradiation tests with high energy protons.
Keywords
Monte Carlo methods; calibration; radiation hardening (electronics); LHC accelerator; Monte Carlo transport codes; SEE; calibration; dedicated radiation monitors; high energy protons; mixed field radiation level measurement; radiation monitors; Large Hadron Collider; Neutrons; Particle beams; Protons; Radiation effects; Random access memory; Uncertainty; CERN; FLUKA; LHC; Monte Carlo; Radiation effects; SEU;
fLanguage
English
Publisher
ieee
Conference_Titel
Radiation and Its Effects on Components and Systems (RADECS), 2011 12th European Conference on
Conference_Location
Sevilla
ISSN
0379-6566
Print_ISBN
978-1-4577-0585-4
Type
conf
DOI
10.1109/RADECS.2011.6131358
Filename
6131358