• DocumentCode
    303444
  • Title

    Moisture dynamic measurements of transformer board using a three-wavelength dielectrometry sensor

  • Author

    Du, Y. ; Zahn, M. ; Mamishev, A.V. ; Schlicker, AndD E.

  • Author_Institution
    Dept. of Electr. Eng. & Comput. Sci., MIT, Cambridge, MA, USA
  • Volume
    1
  • fYear
    1996
  • fDate
    16-19 Jun 1996
  • Firstpage
    53
  • Abstract
    The spatial distribution of dielectric permittivity and conductivity of an insulating medium affects the quasistatic distribution of the electric field. Multiple wavelength interdigital sensors using the imposed frequency-wavenumber (ω-k) dielectrometry technique can measure complex permittivity distributions in dielectrics. Measurements of oil-free and oil-impregnated pressboard transformer insulation using a three-wavelength sensor with changes in ambient moisture concentration are presented. With a calibrated mapping relating conductivity and permittivity to moisture concentration in oil-impregnated pressboard, the spatial distribution of moisture can be measured
  • Keywords
    insulation testing; ambient moisture concentration; calibrated mapping; dielectric conductivity; dielectric permittivity; insulating medium; insulation breakdown tests; moisture dynamic measurements; pressboard transformer insulation; quasistatic electric field distribution; spatial distribution; three-wavelength dielectrometry sensor; Conductivity; Dielectrics; Electrodes; Frequency; Humidity; Moisture measurement; Temperature sensors; Testing; Voltage; Wavelength measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation, 1996., Conference Record of the 1996 IEEE International Symposium on
  • Conference_Location
    Montreal, Que.
  • ISSN
    1089-084X
  • Print_ISBN
    0-7803-3531-7
  • Type

    conf

  • DOI
    10.1109/ELINSL.1996.549281
  • Filename
    549281