DocumentCode :
3039411
Title :
Critical factors on the hermetic characteristics of DC/DC power module
Author :
Li Xunping ; He Xiaoqi ; En YunFei ; Guo Qi
Author_Institution :
5th Electron. Res. Inst., Sci. & Technol. on Reliability Phys. & Applic. of Electron. Component Lab., Minist. of Inf. Ind., Guangzhou, China
fYear :
2013
fDate :
15-19 July 2013
Firstpage :
645
Lastpage :
649
Abstract :
The hermeticity of DC/DC power module was analyzed by using finite element thermal analysis software ANSYS to address the critical factors on the reliability issues of glass insulator (or hermeticity). It was found that shell structure parameters, such as the diameter and shape of hole, the thickness of cover and bottom board, especially the boundary constraints make significant influences on the hermitcity of DC/DC during assembly and testing.
Keywords :
DC-DC power convertors; finite element analysis; reliability; thermal analysis; ANSYS; DC-DC power module hermetic characteristics; boundary constraints; finite element thermal analysis software; shell structure parameters; Ceramics; Educational institutions; Finite element analysis; Integrated circuits; Reliability; Substrates; Thermal conductivity; Critical facotr; DC/DC; FEA; Glass insulator; Hermetic;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Physical and Failure Analysis of Integrated Circuits (IPFA), 2013 20th IEEE International Symposium on the
Conference_Location :
Suzhou
ISSN :
1946-1542
Print_ISBN :
978-1-4799-1241-4
Type :
conf
DOI :
10.1109/IPFA.2013.6599243
Filename :
6599243
Link To Document :
بازگشت