• DocumentCode
    3040405
  • Title

    Development of a high resolution PXI based data acquisition system for electron momentum spectrometer

  • Author

    Huang, Yi-Pai ; Liu, Siyuan ; Wang, Jiacheng ; Hu, Xiaonan ; Feng, C. ; An, Qun-Tao

  • Author_Institution
    State Key Lab. of Particle Detection & Electron., Univ. of Sci. & Technol. of China, Hefei, China
  • fYear
    2012
  • fDate
    9-15 June 2012
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    A high resolution PXI based data acquisition system is developed for a new electron momentum spectrometer constructed in the University of Science and Technology of China (USTC). This system concludes the detection of two outgoing electrons and the detection of ion, which is for more research on collision dynamics. This system mainly consists of a 9-channels time digitization module and a 6-channels charge digitization module, which are assembled in 6U PXI chassis. Related amplifiers are placed near the spectrometer. The measurement of charge involves charge sensitive preamplifier and the technology of digital peak detection. With the preamplifier constructed by discrete devices and charge digitization module, the accuracy of charge measurement can reach up to about 0.6%.Using the technology of TDC implemented in a field-programmable gate arrays (FPGA) from Xilinx Vertex IV family, the average bin size of time measurement can reach up to about 48ps, while the standard deviation is less than 30ps.
  • Keywords
    charge measurement; data acquisition; electron detection; electron spectrometers; field programmable gate arrays; nuclear electronics; preamplifiers; time measurement; 6-channel charge digitization module; 6U PXI chassis; 9-channel time digitization module; China; University of Science and Technology; Xilinx Vertex IV family; charge digitization module; charge measurement accuracy; charge sensitive preamplifier; collision dynamics; digital peak detection technology; discrete devices; electron momentum spectrometer; field-programmable gate arrays; high resolution PXI based data acquisition system; ion detection; outgoing electron detection; time measurement; Anodes; Charge measurement; Data acquisition; Educational institutions; Field programmable gate arrays; Preamplifiers; Timing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Real Time Conference (RT), 2012 18th IEEE-NPSS
  • Conference_Location
    Berkeley, CA
  • Print_ISBN
    978-1-4673-1082-6
  • Type

    conf

  • DOI
    10.1109/RTC.2012.6418154
  • Filename
    6418154