• DocumentCode
    3041319
  • Title

    A two-threshold detector for pulses of unknown duration and doppler

  • Author

    Plant, J.R. ; Chan, Y.T.

  • Author_Institution
    Royal Military College of Canada, Kingston, Ontario
  • Volume
    5
  • fYear
    1980
  • fDate
    29312
  • Firstpage
    630
  • Lastpage
    633
  • Abstract
    The problem of detecting pulses of unknown duration and doppler in gaussian noise is solved using a two threshold detector and averaging. The performance of the detector is estimated using a novel gaussian approximation. The detector has possible application in variable pulse length or multiple pulsed active sonars and radars and also in passive counter measure systems. It is shown that a passive counter measure using the proposed two threshold detector will outperform an active transceiver in an encounter.
  • Keywords
    Counting circuits; Detectors; Doppler radar; Gaussian approximation; Gaussian noise; Pulse measurements; Radar detection; Sonar applications; Sonar detection; Sonar measurements;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Acoustics, Speech, and Signal Processing, IEEE International Conference on ICASSP '80.
  • Type

    conf

  • DOI
    10.1109/ICASSP.1980.1170959
  • Filename