DocumentCode
3041319
Title
A two-threshold detector for pulses of unknown duration and doppler
Author
Plant, J.R. ; Chan, Y.T.
Author_Institution
Royal Military College of Canada, Kingston, Ontario
Volume
5
fYear
1980
fDate
29312
Firstpage
630
Lastpage
633
Abstract
The problem of detecting pulses of unknown duration and doppler in gaussian noise is solved using a two threshold detector and averaging. The performance of the detector is estimated using a novel gaussian approximation. The detector has possible application in variable pulse length or multiple pulsed active sonars and radars and also in passive counter measure systems. It is shown that a passive counter measure using the proposed two threshold detector will outperform an active transceiver in an encounter.
Keywords
Counting circuits; Detectors; Doppler radar; Gaussian approximation; Gaussian noise; Pulse measurements; Radar detection; Sonar applications; Sonar detection; Sonar measurements;
fLanguage
English
Publisher
ieee
Conference_Titel
Acoustics, Speech, and Signal Processing, IEEE International Conference on ICASSP '80.
Type
conf
DOI
10.1109/ICASSP.1980.1170959