DocumentCode
3041836
Title
Live demonstration: Implantable stimulator for epileptic seizure suppression with loading impedance adaptability
Author
Ming-Dou Ker ; Wei-Ling Chen ; Chun-Yu Lin
Author_Institution
Inst. of Electron., Nat. Chiao Tung Univ., Hsinchu, Taiwan
fYear
2012
fDate
28-30 Nov. 2012
Firstpage
78
Lastpage
78
Abstract
An implantable stimulator for epileptic seizure suppression with loading impedance adaptability [1] is demonstrated in the Conference. The stimulator consisted of a high voltage generator, an output driver, an adaptor, and switches, has been integrated in a silicon chip. The fabricated chip of the stimulator has been applied to a closed-loop epileptic seizure monitoring and controlling system [2] for animal test. The measurement setup with the equipments is shown in Fig. 1. The implantable stimulator with Long-Evans rat is shown in Fig. 2. All these experimental procedures have been reviewed and approved by Institutional Animal Care and Use Committee of National Cheng Kung University, Taiwan. The implantable stimulator to suppress the epileptic seizure of the Long-Evans rat will be demonstrated in the Conference. The electroencephalography (EEG) signals of the Long-Evans rat without and with applying the stimulation is presented in the Conference, as shown in Fig. 3. In Fig. 3(a), the epileptic discharges are observed during 3.5~12 s. When the seizure controller is applied in Fig. 3(b), the seizure is detected during 3.5~5.5 s. Upon the detection of the seizure, the intensive and rapidly brain activities are suppressed by the stimulation.
Keywords
bioelectric potentials; biomedical equipment; controllers; electroencephalography; elemental semiconductors; medical signal processing; neurophysiology; patient monitoring; semiconductor switches; silicon; EEG; Institutional Animal Care-and-Use Committee-of-National Cheng Kung University; Long-Evans rat; Si; Taiwan; adaptor; animal testing; brain activity; closed-loop epileptic seizure monitoring; controlling system; electroencephalography signals; epileptic seizure suppression; high voltage generator; implantable stimulator; loading impedance adaptability; measurement setup; output driver; seizure controller; silicon chip; switches; time 3.5 s to 5.5 s; Animals; Biomedical electronics; Educational institutions; Electroencephalography; Impedance; Loading;
fLanguage
English
Publisher
ieee
Conference_Titel
Biomedical Circuits and Systems Conference (BioCAS), 2012 IEEE
Conference_Location
Hsinchu
Print_ISBN
978-1-4673-2291-1
Electronic_ISBN
978-1-4673-2292-8
Type
conf
DOI
10.1109/BioCAS.2012.6418224
Filename
6418224
Link To Document