Title :
Compactness factors for rolled, stacked-screen regenerators
Author :
Murphy, Tim ; Bowman, W. Jerry
Author_Institution :
Air Force Inst. of Technol., Wright-Patterson AFB, OH, USA
Volume :
3
fYear :
1996
fDate :
11-16 Aug 1996
Firstpage :
1873
Abstract :
The objective for the research was to determine how the heat transfer and pressure drop characteristics changed in a stacked, wire-screen regenerator, if the screens which were used to construct the matrix were rolled to decrease their thickness, thereby reducing the volume of the regenerator. Reducing the “dead volume” for regenerative refrigeration cycles was the ultimate motivation for this research. The results show the compactness factor (jH/f) is adversely affected by rolling. Flattening the screens by 15, 30, or 50%, does not cause a new mechanism for heat transfer to be introduced to the matrix, but it does increase the total pressure drop. Rolling the screens causes a decrease in both wetted surface area and pore size, hence, surface phenomena like heat transfer are reduced, but, the inertial pressure drop increases. The effectiveness of the regenerator is also reduced by rolling the screens
Keywords :
flow; flow through porous media; friction; heat transfer; porous materials; refrigeration; compactness factor; dead volume reduction; friction factor; heat transfer; pore size; porous matrix; pressure drop characteristics; regenerative refrigeration cycles; rolled stacked-screen regenerators; surface phenomena; wetted surface area; Electron microscopy; Extraterrestrial measurements; Friction; Heat transfer; Radio frequency; Refrigeration; Space technology; Testing; Wire;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Energy Conversion Engineering Conference, 1996. IECEC 96., Proceedings of the 31st Intersociety
Conference_Location :
Washington, DC
ISSN :
1089-3547
Print_ISBN :
0-7803-3547-3
Type :
conf
DOI :
10.1109/IECEC.1996.553388
Filename :
553388
Link To Document :
بازگشت