DocumentCode :
3045771
Title :
Life extension of thyratrons in short pulse circuits with the use of saturable magnetic sharpeners
Author :
Rust, Ken ; McDuff, Glen
Author_Institution :
Los Alamos Nat. Lab., NM, USA
fYear :
1990
fDate :
26-28 Jun 1990
Firstpage :
290
Lastpage :
301
Abstract :
Recent developments in dispenser cathode thyratrons have shifted the dominant life-limiting factor to the anode in high di/dt short-pulse circuits. Calculations and measurements indicate that the addition of a magnetic switch should reduce the anode temperature and the erosion rate. The addition of a saturating magnetic switch has several advantages. First, by reducing the amount of anode dissipation during the commutation phase of the thyratron, it reduces cooling requirements. Second, it reduces the switching time in a thyratron limited circuit; and third, it can decrease the amount of anode damage due to high-energy electrons associated with the commutation phase or anode fall. The saturating magnetic switch allows the anode voltage to collapse while delaying the forward current, thus reducing the electron energy to a level below that which results in erosion
Keywords :
electrodes; magnetic switching; pulsed power technology; thyratrons; wear; anode fall; anode temperature; commutation phase; cooling requirements; dispenser cathode thyratrons; erosion rate; life extension; life-limiting factor; magnetic switch; saturable magnetic sharpeners; short pulse circuits; switching time; Anodes; Cathodes; Cooling; Electrons; Magnetic switching; Pulse circuits; Saturation magnetization; Switches; Temperature; Thyratrons;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Modulator Symposium, 1990., IEEE Conference Record of the 1990 Nineteenth
Conference_Location :
San Diego, CA
Type :
conf
DOI :
10.1109/MODSYM.1990.200986
Filename :
200986
Link To Document :
بازگشت