• DocumentCode
    305145
  • Title

    Behavior of medium voltage EPR cables designed for operation under high electrical fields

  • Author

    Wen, Yingli ; Cinquemani, Paul L.

  • Author_Institution
    Pirelli Cable Corp., Lexington, SC, USA
  • Volume
    1
  • fYear
    1996
  • fDate
    20-23 Oct 1996
  • Firstpage
    315
  • Abstract
    Medium voltage cable incorporating high stress design with the appropriate EPR insulation demonstrated a significant safety margin when subjected to both AEIC CS6-87 and CS6-96 qualification test. This indicates that high stress designed EPR cables can operate on typical utility network systems as PILC replacements. This is confirmed by the AEIC design of l/O AWG, 35 kV, 8.76 mm (345 mil) insulation, which has been in operation for over 20 years with a excellent service record. The test results also show that Weibull statistical analysis can be used to assess and verify a particular design of medium voltage cables
  • Keywords
    Weibull distribution; ethylene-propylene rubber; insulation testing; mechanical testing; power cable insulation; power cable testing; power cables; statistical analysis; 35 kV; 8.76 mm; AEIC CS6-87 qualification test; AEIC CS6-96 qualification test; EPR insulation; MV cables; PILC replacement; Weibull statistical analysis; high electrical fields; high stress design; mechanical tests; medium voltage EPR cables; safety margin; utility network systems; Cable insulation; Conductors; Dielectrics and electrical insulation; Manufacturing; Mechanical cables; Medium voltage; Paramagnetic resonance; Standards organizations; Statistics; Stress;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation and Dielectric Phenomena, 1996., IEEE 1996 Annual Report of the Conference on
  • Conference_Location
    Millbrae, CA
  • Print_ISBN
    0-7803-3580-5
  • Type

    conf

  • DOI
    10.1109/CEIDP.1996.564690
  • Filename
    564690