• DocumentCode
    3053064
  • Title

    Initial clinical tests for assessment models of synergy movements of stroke patients using PLEMO system with sensor grip device

  • Author

    Ozawa, Takuya ; Kikuchi, Takehito ; Fukushima, Kazuki ; Akai, Hiroki ; Fukuda, Takahiro ; Tanida, Sosuke ; Fujikawa, Takamitsu ; Kano, Shigeaki ; Furusho, Junji

  • Author_Institution
    Rehabilitation Sect., Kano Gen. Hosp., Osaka, Japan
  • fYear
    2009
  • fDate
    23-26 June 2009
  • Firstpage
    873
  • Lastpage
    878
  • Abstract
    In recent years, many researchers have studied on the rehabilitation robotics to assist medical staff or patients. Some kinds of haptic devices have been developed and evaluated its efficiency with clinical tests, for example, upper limb training for patients with spasticity after stroke. Almost all the devices for upper limb rehabilitation have only 2-DOF for its active motion except for wrists. But the upper limb of human works in 3-D space even except for the wrist; therefore designing a rehabilitation system for 3-D training is important. To meet this demand, we have developed a rehabilitation system for upper limbs, ldquoPLEMOrdquo. PLEMO is a kind of haptic device. However, in the previous system, we could not detect symptoms of abnormal movement of patients, for example synergy patterns of stroke patients, because of a lack of sensors. In this paper, we developed new sensing device for detecting such abnormal symptoms. The purpose of this study is to build an appropriate evaluation system for stroke patients with such information of abnormal symptoms. As a first step, we conducted reaching/pulling tests with this device. In this clinical evaluation, the subject is six stroke patients with different Brunnstrom stages (3, 4, 5) and twenty seven healthy subjects. By comparison with a patient movement (stage 3, 4, 5) and a normal movement, we recognized some differences of gripping forces, grip rotation angle and ground reaction forces among their movements.
  • Keywords
    biomechanics; force sensors; grippers; haptic interfaces; medical robotics; patient rehabilitation; 3-D training; PLEMO system; abnormal movement; assessment models; grip force sensor; grip rotation angle; gripping forces; ground reaction forces; haptic device; pulling test; reaching test; rehabilitation robotics; sensor grip device; stroke patients; synergy movements; synergy patterns; upper limb; Extremities; Force sensors; Haptic interfaces; Hospitals; Humans; Medical tests; Rehabilitation robotics; Sensor systems; System testing; Wrist; Clinical evaluation; Electrorheological fluid; Force feedback; Haptic device; Rehabilitation robotics;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Rehabilitation Robotics, 2009. ICORR 2009. IEEE International Conference on
  • Conference_Location
    Kyoto International Conference Center
  • ISSN
    1945-7898
  • Print_ISBN
    978-1-4244-3788-7
  • Electronic_ISBN
    1945-7898
  • Type

    conf

  • DOI
    10.1109/ICORR.2009.5209588
  • Filename
    5209588