Abstract
Lead-free flux used in lead-free solder ball attachment process has been found to play a vital role in improving lead-free solder joint robustness & performance. In this study, two water soluble lead-free solder ball attach fluxes, flux A & flux B, each from different supplier, were compared in terms of the following characteristics: time variation of flux properties, flux stability vs. temperature change, flux wetting through Ni/Au reflow coupon test, and flux performance during & after ball attach process. It was also found that ball attach reflow profile has to be optimized for individual flux type according to the flux properties. Result shows that lead-free flux B performs better than flux A in terms of flux stability over time & temperature, wetting ability, cold ball pull (CBP) & ball shear result with lower brittle fracture rate.
Keywords
solders; ball shear; brittle fracture rate; cold ball pull; flux stability; lead-free flux effect; lead-free solder ball attachment process; lead-free solder joint improvement; temperature change; time variation; water soluble lead-free solder ball; wetting ability; Electronics packaging; Environmentally friendly manufacturing techniques; Gold; Lead compounds; Manufacturing processes; Oxidation; Soldering; Stability; Temperature; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Electronics Manufacturing and Technology, 31st International Conference on
Conference_Location
Petaling Jaya
ISSN
1089-8190
Print_ISBN
978-1-4244-0730-9
Electronic_ISBN
1089-8190
Type
conf
DOI
10.1109/IEMT.2006.4456509
Filename
4456509
Link To Document