DocumentCode
3057680
Title
Medical environment spot exposure: A solid state personal dosimeter
Author
Dario, Rita ; Mundo, Anna ; Leaci, Angela ; Di Lecce, Vincenzo ; Uva, Jessica ; Bianco, Giovanni
Author_Institution
D.M.P.O., ASL BARI - PO San Paolo, Bari, Italy
fYear
2010
fDate
9-9 Sept. 2010
Firstpage
19
Lastpage
25
Abstract
The pollutant presence in hospital is regulated for biological and environmental risk monitoring. Typically, biological and chemical samplers are used to obtain information about air quality and air biological contamination according to European policy and regulations. Currently, air quality data are available to the hospital direction after a few weeks from environmental sampling. In this paper the results of a real-time monitoring obtained using Taguchi Gas Sensors are presented (for VOCs, CO2, CO). From all tests it is clear that the device is valid for the characteristics of sensitivity, accuracy and precision because it can detect the presence/absence of pollutants in a given location.
Keywords
air pollution measurement; carbon compounds; contamination; dosimeters; gas sensors; health hazards; hospitals; organic compounds; CO; CO2; Taguchi gas sensors; accuracy; air biological contamination; air quality; biological risk monitoring; environmental risk monitoring; hospital; medical environment spot exposure; pollutant presence; precision; real-time monitoring; sensitivity; solid state personal dosimeter; Ethanol; Gas detectors; Gases; Hospitals; Monitoring; Surgery; Hospital; Indoor; Pollution; Sampling;
fLanguage
English
Publisher
ieee
Conference_Titel
Environmental Energy and Structural Monitoring Systems (EESMS), 2010 IEEE Workshop on
Conference_Location
Taranto
Print_ISBN
978-1-4244-6274-2
Type
conf
DOI
10.1109/EESMS.2010.5634174
Filename
5634174
Link To Document