• DocumentCode
    3058406
  • Title

    The correlation radiometer- A new application in MM-wave total power radiometry

  • Author

    Gaier, Todd ; Tanner, Alan ; Kangaslahti, Pekka ; Boon Lim

  • Author_Institution
    Jet Propulsion Lab., California Inst. of Technol., Pasadena, CA, USA
  • fYear
    2013
  • fDate
    21-26 July 2013
  • Firstpage
    1924
  • Lastpage
    1926
  • Abstract
    We describe the design and performance of a 180 GHz correlation radiometer suitable for remote sensing. The radiometer provides continuous comparisons between a the observed signal and a reference load to provide stable radiometric baselines. The radiometer was assembled and tested using parts from the GeoSTAR-II instrument and is fully compatible with operation in a synthetic aperture radiometer or as a standalone technology for use in microwave sounding and imaging . This new radiometer was tested over several days easily demonstrating the required 6 hour stability requirement for observations of mean brightness temperature for a geostationary instrument.
  • Keywords
    geophysical equipment; microwave imaging; radiometers; remote sensing; GeoSTAR-II instrument; MM-wave total power radiometry; correlation radiometer; frequency 180 GHz; microwave imaging; microwave sounding; radiometric baseline; remote sensing; synthetic aperture radiometer; Correlation; Microwave radiometry; Noise; Receivers; Temperature measurement; Temperature sensors; Thermal stability; MMICs; Microwave radiometry;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Geoscience and Remote Sensing Symposium (IGARSS), 2013 IEEE International
  • Conference_Location
    Melbourne, VIC
  • ISSN
    2153-6996
  • Print_ISBN
    978-1-4799-1114-1
  • Type

    conf

  • DOI
    10.1109/IGARSS.2013.6723181
  • Filename