• DocumentCode
    3060089
  • Title

    Accuracy of lumped-element calibrations for four-sampler vector network analyzers

  • Author

    Marks, R.B. ; Jargon, J.A. ; Rytting, D.K.

  • Author_Institution
    Nat. Inst. of Stand. & Technol., Boulder, CO, USA
  • Volume
    3
  • fYear
    1998
  • fDate
    7-12 June 1998
  • Firstpage
    1487
  • Abstract
    Several lumped-element calibrations have been proposed for four-sampler vector network analyzers. This paper offers the first assessment of their accuracy in the face of imperfectly defined standards. We discover significant error and introduce a new calibration that offers demonstrably improved accuracy.
  • Keywords
    calibration; lumped parameter networks; network analysers; SOLT; four-sampler vector network analyzer; lumped-element calibration; Calibration; Government; Measurement errors; Measurement standards; NIST; Postal services; Proposals; Reflection; Robustness; Test equipment;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave Symposium Digest, 1998 IEEE MTT-S International
  • Conference_Location
    Baltimore, MD, USA
  • ISSN
    0149-645X
  • Print_ISBN
    0-7803-4471-5
  • Type

    conf

  • DOI
    10.1109/MWSYM.1998.700656
  • Filename
    700656