Abstract :
A new technique for accurate fault location and protection of distribution cable is presented in the paper. A specially designed transient capturing unit is used to extract the fault generated high frequency voltage transient signals from the distribution cable system. The travelling time of the high frequency signal is used to determine the fault position. The scheme is insensitive to fault type, fault resistance, fault inception angle and system source configuration. Studies show that the proposed technique is able to offer a very high accuracy in both fault location and fault detection
Keywords :
distribution networks; fault location; power cables; power system protection; transient analysis; underground cables; underground distribution systems; fault detection; fault generated high frequency voltage transients; fault location; fault position determination; high frequency signal; power cable; protection scheme; transient capturing unit; travelling time; underground distribution systems; Fault detection; Fault location; Frequency; Power cables; Power generation; Power system transients; Protection; Signal generators; Transducers; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrotechnical Conference, 1996. MELECON '96., 8th Mediterranean
Conference_Location :
Bari
Print_ISBN :
0-7803-3109-5
Type :
conf
DOI :
10.1109/MELCON.1996.551330
Filename :
551330
Link To Document :
بازگشت