• DocumentCode
    3060626
  • Title

    Design of lower limb prosthesis with contact pressure adjustment by MR fluid

  • Author

    Ogawa, Atsuo ; Obinata, Goro ; Hase, Kazunori ; Dutta, Ashish ; Nakagawa, Miyoshi

  • Author_Institution
    Nagoya University & Japan College of Rehabilitation and Welfare Professionals, (Dept. of Prosthetics & Orthotics), Furo-Cho, Chikusa-ku, Japan
  • fYear
    2008
  • fDate
    20-25 Aug. 2008
  • Firstpage
    330
  • Lastpage
    333
  • Abstract
    This paper reports on the development of a new lower limb prosthesis that can change its volume and hardness based on the users requirements. The size and viscosity of several Magneto-Rheological fluid filled bags, fixed on the inner side of the socket is changed, in order to vary the socket properties. TSB (total surface bearing) sockets have been most selling ones during these two decades. From the user´s point of view, it is excellent in this type of sockets that the weight of user is supported with the entire socket surface. However, it is impossible to cope with the volume change of the user´s stump. Experimental results show that the performance of the developed MR socket is better than the conventional TSB sockets because the MR socket is controllable in the size and viscosity.
  • Keywords
    Fluid dynamics; Force measurement; Knee; Leg; Legged locomotion; Magnetic materials; Orthotics; Prosthetics; Sockets; Viscosity; Artificial Limbs; Equipment Design; Equipment Failure Analysis; Humans; Knee Joint; Lower Extremity; Magnetics; Pressure; Prosthesis Fitting; Rheology;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2008. EMBS 2008. 30th Annual International Conference of the IEEE
  • Conference_Location
    Vancouver, BC
  • ISSN
    1557-170X
  • Print_ISBN
    978-1-4244-1814-5
  • Electronic_ISBN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/IEMBS.2008.4649157
  • Filename
    4649157