    Film-type transducer materials PVDF and EMFi in the measurement of heart and respiration rates

  • Author

    Kärki, Satu ; Lekkala, Jukka

  • Author_Institution
    Department of Automation Science and Engineering, Tampere University of Technology, P.O. Box 692, FI-33101, Finland
  • fYear
    2008
  • fDate
    20-25 Aug. 2008
  • Firstpage
    530
  • Lastpage
    533
  • Abstract
    Film-type transducer materials polyvinylidenefluoride (PVDF) and ElectroMechanical Film (EMFi) were used in the measurement of heart and respiration rates on the chest wall at rest. The aim here was to evaluate if the both materials are capable to measure the heart and respiration rates correctly and also to found out if there are differences between the results of PVDF and EMFi. The movements provided by the pulsation of heart and respiration were converted into an electrical signal by the sensors. The signals were amplified and transmitted to a computer. The data was analyzed with Matlab® software. The signals were filtered to reveal the heart pulsation and respiration components. Power spectral density (PSD) spectrum was computed to determine the heart and respiration rates. ECG was used as a reference signal for the heart rate and a thermistor for the respiration rate. Both transducer materials provided good results and no differences between PVDF and EMFi were found. The heart rates measured with PVDF and EMFi sensors corresponded to the values calculated from the ECG signal. Also the respiration rates correlated with the values determined with the thermistor. To conclude, both materials provided reliable results in the measurements of heart and respiration rates.
  • Keywords
    Biological materials; Biomedical monitoring; Blood; Electrocardiography; Force measurement; Heart rate; Pulse measurements; Thermistors; Transducers; Wearable sensors; Electrocardiography; Equipment Design; Equipment Failure Analysis; Heart Rate; Humans; Materials Testing; Membranes, Artificial; Polyvinyls; Reproducibility of Results; Respiratory Function Tests; Respiratory Mechanics; Sensitivity and Specificity; Transducers;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2008. EMBS 2008. 30th Annual International Conference of the IEEE
  • Conference_Location
    Vancouver, BC
  • ISSN
    1557-170X
  • Print_ISBN
    978-1-4244-1814-5
  • Electronic_ISBN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/IEMBS.2008.4649207
  • Filename
    4649207