DocumentCode
3061686
Title
Millimeter wave imaging applied in reflectometry and radiometry to diagnose thermonuclear plasmas
Author
Van de Pol, M.J. ; Classen, I.G.J. ; Domier, C.W. ; Donné, A. J H ; Johnson, M. ; Luhmann, N.C., Jr. ; Mazzucato, E. ; Munsat, T. ; Park, H. ; Wang, J. ; Xia, Z.
Author_Institution
FOM, Inst. for Plasma Phys., Rijnhuizen, Netherlands
fYear
2004
fDate
27 Sept.-1 Oct. 2004
Firstpage
709
Lastpage
710
Abstract
The application of large collection optics to image millimeter waves on a detector array improves the spatial resolution and enables the recovery of small-scale structures and fluctuation characteristics of the plasma electron temperature and density from radiometer and reflectometer measurements. Both diagnostic techniques are combined into a single instrument on the TEXTOR tokamak.
Keywords
Tokamak devices; microwave reflectometry; millimetre wave imaging; photometry; plasma density; plasma diagnostics; plasma fluctuations; plasma temperature; plasma waves; TEXTOR tokamak; detector array; millimeter wave imaging; plasma electron temperature; plasma fluctuation; radiometer measurements; reflectometer measurements; small-scale structures; spatial resolution; thermonuclear plasma diagnosis; Millimeter wave technology; Plasma applications; Plasma density; Plasma diagnostics; Plasma measurements; Plasma properties; Plasma temperature; Plasma waves; Radiometry; Reflectometry;
fLanguage
English
Publisher
ieee
Conference_Titel
Infrared and Millimeter Waves, 2004 and 12th International Conference on Terahertz Electronics, 2004. Conference Digest of the 2004 Joint 29th International Conference on
Print_ISBN
0-7803-8490-3
Type
conf
DOI
10.1109/ICIMW.2004.1422288