DocumentCode :
3062613
Title :
Development of a technique for high frequency audiometry
Author :
Krasner, M.A. ; Stevens, K.N. ; Green, D.M. ; Blumenthal, S.H.
Author_Institution :
Bolt Beranek and Newman, Inc., Cambridge, MA
Volume :
8
fYear :
1983
fDate :
30407
Firstpage :
1400
Lastpage :
1403
Abstract :
In this paper, we describe the development of a new technique for the assessment of hearing thresholds in the range 8-20 kHz. We describe a model that circumvents some major difficulties encountered by present audiometric methods at high frequencies, and we present measurements that validate that model. A technique that can provide accurate and reliable measurements is described and evaluated.
Keywords :
Bandwidth; Ear; Fasteners; Frequency measurement; Impedance; Irrigation; Poles and zeros; Pressure measurement; Resonance; Transfer functions;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Acoustics, Speech, and Signal Processing, IEEE International Conference on ICASSP '83.
Type :