• DocumentCode
    3063601
  • Title

    The electronic ballast using Class-E rectifier with tapped inductor for power factor correction

  • Author

    Sasiluk, J. ; Kamon, J.

  • Author_Institution
    Faculty of Enginering, king mongkut´s university of technology thonburi, 126 Pracha utid road, Bangmod, Toongkru, Thailand
  • fYear
    2009
  • fDate
    8-11 Feb. 2009
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    In this paper present the electronic ballast using class-E rectifier with tapped inductor for power factor correction. The inductance load of electronic ballast, is crest factor occurring. Class-E rectifier is used for power factor correction. The low line harmonic obtained from class-E rectifier that inserted between the fort end bride rectifier and the bulk filter capacitor, for increase the conduction angle of the bridge rectifier diode current. While, impedance matching obtained a high frequency tapped inductor. The simulation for 36 W ballast at full power. Present power factor was 0.99, the total efficiency was 90%, and the lamp crest factor was 1.41. The experimental for the prototype ballast. Present power factor 0.99, the total efficiency 86%, THD 5.6%. The proposed are high power factor, low harmonic in line current, smaller size and weight, and economic cost.
  • Keywords
    Bridges; Capacitors; Diodes; Electronic ballasts; Inductance; Inductors; Power factor correction; Power harmonic filters; Reactive power; Rectifiers; Class-E rectifier; High power factor; ZVS; low crest factor; tapped Inductor;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Intelligent Signal Processing and Communications Systems, 2008. ISPACS 2008. International Symposium on
  • Conference_Location
    Bangkok, Thailand
  • Print_ISBN
    978-1-4244-2564-8
  • Electronic_ISBN
    978-1-4244-2565-5
  • Type

    conf

  • DOI
    10.1109/ISPACS.2009.4806768
  • Filename