Title :
Noninvasive Continuous Blood Pressure Measurement and GPS Position Monitoring of Patients
Author :
Krejcar, Ondrej ; Slanina, Zdenek ; Stambachr, Jan ; Silber, Petr ; Frischer, Robert
Author_Institution :
Dept. of Meas. & Control, Tech. Univ. of Ostrava, Ostrava, Czech Republic
Abstract :
Need of blood pressure measurement is usable in wide spectrum of applications from physicians offices to home care applications. Many types of blood pressure measurement devices can be bought in electronics shops. All such devices are measurement devices which need to be in contact with human body (hand or foot mainly). Further they allow only one measurement per several minutes interval (typically 10 minutes). Our goal is to develop a small device for noninvasive continuous measurement of blood pressure. This device must be a small battery powered embedded system which measures a blood pressure during a long time period and sends this information to remote operator´s stations. In this station the analysis of receiving video data is made for several types of usage. In current state we develop a small device to scan a video or a set of images with the NIR (Near Infra Red) CCD camera. The video data are transferred by wireless connection to the computer where they are analyzed. The first results provide an indication to be a right way to obtain exact continuous blood pressure information. In the future there exists a way to integrate this blood pressure measurement system to concurrently developed biotelemetric system architecture for patients and physicians called Guardian. For position monitoring in outdoor areas there is developed GPS module which informs about patient location and brings very precise time basis for other measuring modules of Guardian system and time synchronization.
Keywords :
Global Positioning System; biomedical telemetry; blood pressure measurement; patient monitoring; GPS position monitoring; Guardian system; battery powered embedded system; biotelemetric system architecture; electronics shop; near infra red CCD camera; noninvasive continuous blood pressure measurement; patient monitoring; wireless connection; Battery charge measurement; Biomedical monitoring; Blood pressure; Foot; Global Positioning System; Humans; Patient monitoring; Position measurement; Pressure measurement; Time measurement;
Conference_Titel :
Vehicular Technology Conference Fall (VTC 2009-Fall), 2009 IEEE 70th
Conference_Location :
Anchorage, AK
Print_ISBN :
978-1-4244-2514-3
Electronic_ISBN :
1090-3038
DOI :
10.1109/VETECF.2009.5378905