Title :
An automatic psychrometer sensor for poultry farming
Author :
Nichols, E.L., IV
Author_Institution :
Westinghouse Savannah River Co., Aiken, SC, USA
Abstract :
A sensor was developed which utilized the psychrometric process and produced an output proportional to percent relative humidity compatible with existing industry control devices. The wet- and dry-bulb sensors were comprised of two temperature sensors which had already been used successfully for thermostats for poultry farming control systems. A mechanical timer was utilized to automate the psychrometric process. The wet- and dry-bulb signals were digitized, and the result was used to address a psychrometric table stored in read-only memory (ROM) chips. The output from the ROMs was then converted to an analog signal for display and for use by a control system. The testing of the sensor demonstrated that it would produce the proper output within a tolerance of 1% for a range of several known humidities
Keywords :
computerised instrumentation; farming; humidity measurement; signal processing equipment; thermostats; ROM; automatic psychrometer sensor; control; dry-bulb sensors; industry control; mechanical timer; poultry farming; psychrometric process; read-only memory; relative humidity; temperature sensors; thermostats; wet-bulb sensor; Automatic control; Control systems; Electrical equipment industry; Humidity control; Industrial control; Industrial psychology; Mechanical sensors; Proportional control; Read only memory; Temperature sensors;
Conference_Titel :
Southeastcon '92, Proceedings., IEEE
Conference_Location :
Birmingham, AL
Print_ISBN :
0-7803-0494-2
DOI :
10.1109/SECON.1992.202429