DocumentCode
3069848
Title
Effect of filter and compensation unit in the traction power supply at extreme distortion
Author
Vaclav, Kus ; Bohumil, Skala
Author_Institution
Univ. of West Bohemia in Pilsen, Pilsen, Czech Republic
fYear
2013
fDate
5-7 June 2013
Firstpage
7
Lastpage
12
Abstract
The presented paper deals with the associated problems that come up with common installation of filter and compensation unit with decompensation reactor used in traction power supply system. The influence of single-phase traction converter on the traction trolley and load is a specific problem. The locomotives on the line are a source of harmonic currents. This source affects the voltage distortion on the system. Connection of filtration compensation unit significantly sinks the voltage curve distortion, especially at the power supply station. Due to compensation power of filters is necessary present decompensation reactor. This paper describes the steady states and is focused on the possible extreme cases. The influence of filter parameters in cases of extreme distortion has been investigated.
Keywords
compensation; constant current sources; electric locomotives; power harmonic filters; reactors (electric); traction power supplies; trolleys; decompensation reactor; filter effect; filtration compensation unit; harmonic current source; locomotive; power supply station; single-phase traction converter; traction power supply system; traction trolley; voltage curve distortion; voltage distortion; Active filters; Harmonic analysis; Inductors; Power generation; Power harmonic filters; Resonant frequency;
fLanguage
English
Publisher
ieee
Conference_Titel
Compatibility and Power Electronics (CPE), 2013 8th International Conference on
Conference_Location
Ljubljana
ISSN
2166-9538
Print_ISBN
978-1-4673-4911-6
Type
conf
DOI
10.1109/CPE.2013.6601120
Filename
6601120