• DocumentCode
    307591
  • Title

    On the simultaneous fitting for tracer delay and dispersion in cerebral blood flow studies using oxygen-15 water and PET

  • Author

    Toussaint, P.-J. ; Meyer, E.

  • Author_Institution
    Neurological Inst., McGill Univ., Montreal, Que., Canada
  • Volume
    1
  • fYear
    1995
  • fDate
    20-25 Sep 1995
  • Firstpage
    521
  • Abstract
    Simulations were used to evaluate the feasibility of simultaneous estimation of CBF, partition coefficient, tracer delay and dispersion in the one-compartment CBF model by curve fitting. The accuracy and precision of these estimates were investigated by means of sensitivity functions. Despite the considerable variability (up to 50%) in the Δt and τ estimates, estimates of CBF were within 5% of their true values
  • Keywords
    blood flow measurement; brain; curve fitting; positron emission tomography; H2O; PET; curve fitting; medical diagnostic imaging; nuclear medicine; partition coefficient; sensitivity functions; tracer delay; Blood flow; Brain modeling; Delay effects; Delay estimation; Equations; Least squares approximation; Parameter estimation; Performance evaluation; Positron emission tomography; Shape;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 1995., IEEE 17th Annual Conference
  • Conference_Location
    Montreal, Que.
  • Print_ISBN
    0-7803-2475-7
  • Type

    conf

  • DOI
    10.1109/IEMBS.1995.575230
  • Filename
    575230