DocumentCode
3076874
Title
Monitoring of the DFIG of a variable speed wind turbine
Author
Héraud, N. ; Kahyeh, M. Ainan ; Guelle, I. Souleiman
Author_Institution
SPE, Univ. of Corsica, Corte, France
fYear
2010
fDate
8-10 Nov. 2010
Firstpage
440
Lastpage
445
Abstract
This paper addresses the fault detection and isolation issue of wind turbine systems. The underlying problem is very critical to enhance the reliability, the availability and reduce the cost of maintenance of wind turbines. In this work, we use a doubly fed induction generator and a nonlinear observer is utilized to generate the residual for fault detection purpose.
Keywords
asynchronous generators; fault diagnosis; maintenance engineering; observers; reliability; wind turbines; DFIG; doubly fed induction generator; fault detection; fault isolation; nonlinear observer; reliability; variable speed wind turbine; wind turbine maintenance; wind turbine systems; Current measurement; Generators; Mathematical model; Observers; Rotors; Stators; Wind turbines;
fLanguage
English
Publisher
ieee
Conference_Titel
Transmission and Distribution Conference and Exposition: Latin America (T&D-LA), 2010 IEEE/PES
Conference_Location
Sao Paulo
Print_ISBN
978-1-4577-0488-8
Type
conf
DOI
10.1109/TDC-LA.2010.5762919
Filename
5762919